A/RH3-O-4X
Outdoor Humidity Sensor
            by
        
        done_outline8888 in stock
        
            addShow Locations
            removeHide Locations
        
    3% Accuracy, Capacitive With Hydrophobic Filter Sensor Type, NEMA 4X Enclosure, 250 ohm Load, 15-40 VDC/ 18-28 VAC Supply Voltage.
Features
                    Monitor Outdoor Air Humidity, Economizer Control, Psychrometric Calculations Such As Enthalpy And Dew Point, Wash Down Applications
                
                            
                    Utilizes A Thermoset Polymer Capacitive Sensing Element With Factory Applied Hygroscopic Filter To Deliver A Proportional Analog Current Or Voltage Output Signal
                
                            
                    The Hygroscopic Filter Provides Added Resistance To Moisture, Dust, And Other Chemicals For Greater Long Term Reliability
                
                            
                    The RH Outside Air Transmitter Features Integral DIP Switches For Field Selection Of The Proper Output Signal And Supply Voltage To Meet Your Applications Requirements
                
                            
                    Each Unit Also Contains 0%, 50%, And 100% Test Options To Verify That The Transmitter Is Both Working And Wired Properly
                
                            
                    Field Calibration Can Be Performed By Using The Increment And Decrement Calibration DIP Switches Without The Need To Replace The Sensing Element
                
                            
                    Field Selectable, Two Wire
                
                        Technical Details
                            Configuration
                        
                        
                            Outdoor
                        
                    
                            Enclosure
                        
                        
                            NEMA 4
                        
                    
                            Mounting
                        
                        
                            Wall Mount
                        
                    
                            Output Voltage Signal Range
                        
                        
                            0 To 5 V, 0 To 10 V, 4 To 20 mA
                        
                    
                            Sensors Application
                        
                        
                            Humidity