    120 VAC, 50/60 Hz., Lockout Interlocks, 10 Second Or Intermittent Main Flame Establishing Period, Interrupted Second Stage Pilot Valve, Includes S7800 Display, On/Off-LF Proven.
Features
                    Functions Include Automatic Burner Sequencing, Flame Supervision, System Status Indication, System Or Self Diagnostics And Troubleshooting
                
                            
                    Includes Keyboard Display Module
                
                            
                    4 Second Or 10 Second Pilot Flame Establishing Period
                
                            
                    Access For External Electrical Voltage Checks
                
                            
                    Application Flexibility And Communication Interface Capability
                
                            
                    Five LEDs Provide Sequence Information
                
                            
                    Five Function Run/Test Switch
                
                            
                    Interchangeable Plug-In Amplifiers
                
                            
                    Local Or Remote Annunciation Of Operation And Fault Information (Optional)
                
                            
                    Non-Volatile Memory Retains History Files And Lockout Status After Loss Of Power
                
                            
                    Compatible With Existing Honeywell Flame Detectors
                
                        Technical Details
                            Application
                        
                        
                            Programming Control
                        
                    
                            Operating Conditions
                        
                        
                            -40 F To 140 F
                        
                    
                            Early Spark Termination
                        
                        
                            Yes, 5 Seconds
                        
                    
                            Second Stage Pilot Valve:
                        
                        
                            Intermittent
                        
                    
                            Pilot Type:
                        
                        
                            Interrupted
                        
                     